• 本课程为精品课,您可以登录eeworld继续观看:
  • NUMBER ON A CIRCUIT - 210.11(A)​​​​​​​
  • 登录
课程介绍
相关标签: 电子系统
Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

显示全部 ↓
推荐视频

    用户评论

    暂时无评论

    猜您喜欢

    推荐帖子

    艾睿访谈:RoHS绿色环保之路还未到达终点
    [i=s] 本帖最后由 jameswangsynnex 于 2015-3-3 20:00 编辑 [/i]
    rain 移动便携
    煤矿通风系统案例介绍
    同煤集团煤矿通风风机各项参数集中监测系统改造方案煤矿安全事故频繁,给国家造成了巨大损失,造成事故最关键的原因是瓦斯爆炸。而防止瓦斯爆炸最有效的手段就是对矿井排风,目前很多煤窑对的排风风机检测主要靠人工24小时轮流值守,定时观察记录风机个部分温度计示数或现场电子温度计示数。此种方法费时费力,数据反馈不及时。如果值班人员数疏忽造成风机停机会造成重大安全事故。本文介绍了山西同煤集团某煤矿通风风机各项参数
    l380730475 工控电子
    TMS320C6748的GPIO特性
    参考TI技术文档SPRUFL8B(《TMS320C674x/OMAP-L1x Processor GPIO User's Guide》)的1.2Features部分我们可以看出TMS320C6748的GPIO有如下特性:1.可以通过单独的数据设置和清除寄存器来设置/清除GOIO功能和可通过软件在没有critical section保护下控制GPIO(这部分我不理解原文)2.还支持通过写一个
    灞波儿奔 DSP 与 ARM 处理器
    FPGA实现高速传输模块
    [size=6]跪求,请问哪位高手有关于FPGA实现高速传输的源代码或者相关资料?本人在做相关的学习工作,本人的邮箱:[u] [email]ziqiang10@126.com[/email][/u][/size]
    ziqiang10 FPGA/CPLD
    Wince自启动问题
    在设置程序自启动时,我采用两种方法,1、将程序名改为explorer.exe,然后放到Release文件夹里,覆盖原有的explorer.exe,这样做成的bin文件在启动后出现了这个错误:50 was not found2、更改shell.reg。程序名为final.exe[HKEY_LOCAL_MACHINE\init]"Launch50"="explorer.exe""Depend50"=h
    koalaping WindowsCE
    求高人指点 这句程序是什么意思??
    if (ADC_Result < 0x1FF)这是一个条件语句,括号里面的是ADC_Result<111111111(二进制)我主要是不明白ADC_Result是什么?
    1157421908 微控制器 MCU

    推荐内容

    热门视频更多

    可能感兴趣器件

    EEWorld订阅号

    EEWorld服务号

    汽车开发圈

    About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版 版权声明

    站点相关: 汽车电子 智能硬件

    北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

    电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2023 EEWORLD.com.cn, Inc. All rights reserved